A hollow-core slab being lifted into place by crane, the voids visible in its cross-section

There is no minimum order. Every hollow-core slab is cast on our automated production line and delivered to site with our own transport.

Any quantity,
made to your drawings

About Preslabs

We cast hollow-core slabs for residential and industrial buildings, and deliver them to site with our own transport. Five standard depths, cut lengthwise to the width you need, with openings formed in production and no minimum order.

  • 15.7mMax slab length
  • 24tOwn transport per load
  • 5Standard depths
  • REI 60Fire class
The product

Hollow-core floor slabs, cast to your floor plans

Reinforced concrete slabs with round hollow cores, cast on a continuous forming line to the floor plans you send us, with cut-outs, cuts and loads marked.

The slabs are durable, resist moisture and fire, and insulate against heat and sound. We advise on slab choice and carry out the load calculations.

Send your floor plans
Slab (HCS)
4 kPa
Axonometric viewFront face to scale, length shortened to fit, cores shown schematically.
ElementHollow-core HCS 265
Design load4 kPa
Max length L12.4 m
Unitsmm, m
Max slab length 12.4m HCS 265 at 4 kPa design load

All slabs at 4 kPa

Depth H
265 mm
Width B
up to 1200 mm
Self-weight
4.20 kN/m
Fire resistance
REI 60
Full load and length table
How to read the drawing and valuesShowHide
  • Depth, H

    Slab thickness from the underside to the top surface, in millimetres. The number in the slab name is its depth: HCS 265 is 265 mm deep.

  • Width, B

    Up to 1200 mm. Slabs can be cut lengthwise to a narrower width, and loads for narrowed slabs are recalculated.

  • Length, L

    Cut to order. L max is the longest slab permitted at the selected design load.

  • Design load, kPa

    The load per square metre of floor the slab is designed to carry, shown by the arrows on the drawing. 1 kPa is 1 kN/m², about 102 kg per square metre. It is set by the structural engineer for your project.

  • Self-weight

    The weight of one metre of slab. 1 kN/m is about 102 kg per metre of slab length.

  • Fire resistance, REI 60

    The slab keeps its load-bearing capacity (R), integrity (E) and insulation (I) for at least 60 minutes in a standard fire test.

  • Hollow cores

    Round voids running the full length of the slab, which make it lighter than a solid slab of the same depth. Core size depends on the slab parameters.

  • Centre lines

    Dash-dot lines cross at the centre of each hollow core.

  • Shaped long edges

    The profiled edges where neighbouring slabs meet and form the joint between them.

  • Hatching

    Diagonal lines mark the cut face of the concrete, as on standard technical drawings.

  • Axonometric view

    A 3D line drawing. The front face is drawn to scale, the length is shortened to fit, and the cores are shown schematically.

  • Not in table

    Our standard tables give no value for that slab at that load. Send us your plans and we will calculate it.

Values come from our standard slab tables and are for choosing a slab. We carry out the load calculation for your project.

Load tables

Maximum slab length by design load

Find your design load along the top. Each value is the maximum length, in metres, of a standard 1200 mm wide slab at that load. Or enter the length you need to see the highest design load each slab carries at it.

m

Maximum slab length L, mStandard slab, 1200 mm wide. Select a value to show it on the drawing.

  • On the drawing
  • Not in our tables
Maximum permitted slab length in metres by design load in kPa
SlabSelf-weightDesign load, kPaAt your length
4567891011121314151617181920222426
HCS 2003.30 kN/mNot tabulatedNot tabulatedNot tabulated
HCS 2203.90 kN/mNot tabulatedNot tabulatedNot tabulated
HCS 2654.20 kN/mNot tabulatedNot tabulatedNot tabulated
HCS 3204.40 kN/mNot tabulatedNot tabulatedNot tabulated
HCS 4005.00 kN/mNot tabulatedNot tabulatedNot tabulated
  • Loads for slabs cut narrower than 1200 mm are recalculated.
  • HCS 400 is listed from 6 kPa, and in 2 kPa steps above 18 kPa.
  • Use the table to choose a slab. We carry out the load calculations for your project.
In production

Shaped to your floor plan

Send us your floor plans with the openings, cuts and loads marked. Your slabs are cast on our automated production line to match them.

Send your floor plans
Floor viewSlabs lie side by side and span from wall to wall. Numbers match the notes.
1Opening formed in production2Edge slab cut to widthStandard slab, 1200 mm wideWallWall12
  1. 1Opening formed in production
  2. 2Edge slab cut to width

Standard slabs are 1200 mm wide and rest on a wall at each end.

Hollow-core slabs on timber bearers, one with a large rectangular opening formed through it, round cores visible in the slab ends

Openings formed in production

Openings for services, shafts and stairs are formed while the slab is cast. Openings are made only in full 1200 mm wide slabs.

Cut to the width you need

Slabs can be cut lengthwise to the exact width your plan needs. Loads for narrowed slabs are recalculated.

A smooth concrete ceiling of precast floor slabs left exposed in a bright finished room

Smooth ceiling, minimal screed

The ceiling surface needs no extra filling, and the floor levelling layer stays minimal.

Get a quote

Send us your floor plans

Attach your plans with the openings, cuts and loads marked. We check them, calculate the loads and come back with a quote.

  1. 01You send the plansDrawings in any common format, one file or many.
  2. 02We calculate the loadsWe check the slab choice for your spans and loads.
  3. 03You get a quotePriced for your project, with no minimum order.

Prefer to talk? Call +370 621 59911 or email info@concreta.lt.

Your details
Your project
kPa
Drawings and notes
Floor plans

    * Required

    Questions and answers

    Frequently asked questions

    Short answers about choosing, ordering and delivery. For anything specific to your project, ask us directly.

    More questions? Ask us
    Is there a minimum order?

    No. We make any quantity, from a single slab to a whole building, to your drawings.

    What do you need from me for a quote?

    Your floor plans with the openings, cuts and loads marked. The price depends on the slab depth, width, length and load, so the more complete the plans, the more exact the quote.

    How do I choose the right slab?

    Start from the design load your structural engineer gives you and the length you need. The slab tool and load table above show which slabs carry that load at that length. We also carry out the load calculations for your project.

    How long can a slab be?

    It depends on the slab and the load. At 6 kPa, HCS 400 reaches 15.7 m and HCS 200 reaches 9.1 m. The load table above gives every combination.

    Can slabs be narrower than 1200 mm?

    Yes. Slabs can be cut lengthwise to the exact width your plan needs. Loads for narrowed slabs are recalculated.

    Can you make openings for stairs and shafts?

    Yes. Openings for services, shafts and stairs are formed while the slab is cast. Openings are made only in full 1200 mm wide slabs.

    What fire resistance do the slabs have?

    All our standard hollow-core slabs are rated REI 60: they keep their load-bearing capacity, integrity and insulation for at least 60 minutes.

    Are the slabs certified?

    Yes. Our slabs meet building standard requirements and are certified to EU requirements.

    Do the slabs insulate sound and heat?

    Yes. Hollow-core slabs provide heat and sound insulation, and deeper slabs insulate against noise better.

    How long does production take?

    Production takes one month from order confirmation.

    How are the slabs delivered?

    With our own transport, up to 24 t per load. Delivery to Sweden takes 2 to 3 days, and unloading on site is arranged by agreement.