Openings formed in production
Openings for services, shafts and stairs are formed while the slab is cast. Openings are made only in full 1200 mm wide slabs.
There is no minimum order. Every hollow-core slab is cast on our automated production line and delivered to site with our own transport.
About Preslabs
We cast hollow-core slabs for residential and industrial buildings, and deliver them to site with our own transport. Five standard depths, cut lengthwise to the width you need, with openings formed in production and no minimum order.
Reinforced concrete slabs with round hollow cores, cast on a continuous forming line to the floor plans you send us, with cut-outs, cuts and loads marked.
The slabs are durable, resist moisture and fire, and insulate against heat and sound. We advise on slab choice and carry out the load calculations.
Send your floor plansSlab thickness from the underside to the top surface, in millimetres. The number in the slab name is its depth: HCS 265 is 265 mm deep.
Up to 1200 mm. Slabs can be cut lengthwise to a narrower width, and loads for narrowed slabs are recalculated.
Cut to order. L max is the longest slab permitted at the selected design load.
The load per square metre of floor the slab is designed to carry, shown by the arrows on the drawing. 1 kPa is 1 kN/m², about 102 kg per square metre. It is set by the structural engineer for your project.
The weight of one metre of slab. 1 kN/m is about 102 kg per metre of slab length.
The slab keeps its load-bearing capacity (R), integrity (E) and insulation (I) for at least 60 minutes in a standard fire test.
Round voids running the full length of the slab, which make it lighter than a solid slab of the same depth. Core size depends on the slab parameters.
Dash-dot lines cross at the centre of each hollow core.
The profiled edges where neighbouring slabs meet and form the joint between them.
Diagonal lines mark the cut face of the concrete, as on standard technical drawings.
A 3D line drawing. The front face is drawn to scale, the length is shortened to fit, and the cores are shown schematically.
Our standard tables give no value for that slab at that load. Send us your plans and we will calculate it.
Values come from our standard slab tables and are for choosing a slab. We carry out the load calculation for your project.
Find your design load along the top. Each value is the maximum length, in metres, of a standard 1200 mm wide slab at that load. Or enter the length you need to see the highest design load each slab carries at it.
Maximum slab length L, mStandard slab, 1200 mm wide. Select a value to show it on the drawing.
| SlabSelf-weight | Design load, kPa | At your length | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 22 | 24 | 26 | ||
| HCS 2003.30 kN/m | Not tabulated | Not tabulated | Not tabulated | ||||||||||||||||||
| HCS 2203.90 kN/m | Not tabulated | Not tabulated | Not tabulated | ||||||||||||||||||
| HCS 2654.20 kN/m | Not tabulated | Not tabulated | Not tabulated | ||||||||||||||||||
| HCS 3204.40 kN/m | Not tabulated | Not tabulated | Not tabulated | ||||||||||||||||||
| HCS 4005.00 kN/m | Not tabulated | Not tabulated | Not tabulated | ||||||||||||||||||
Send us your floor plans with the openings, cuts and loads marked. Your slabs are cast on our automated production line to match them.
Send your floor plansStandard slabs are 1200 mm wide and rest on a wall at each end.

Openings for services, shafts and stairs are formed while the slab is cast. Openings are made only in full 1200 mm wide slabs.
Slabs can be cut lengthwise to the exact width your plan needs. Loads for narrowed slabs are recalculated.

The ceiling surface needs no extra filling, and the floor levelling layer stays minimal.
Attach your plans with the openings, cuts and loads marked. We check them, calculate the loads and come back with a quote.
Prefer to talk? Call +370 621 59911 or email info@concreta.lt.
Short answers about choosing, ordering and delivery. For anything specific to your project, ask us directly.
No. We make any quantity, from a single slab to a whole building, to your drawings.
Your floor plans with the openings, cuts and loads marked. The price depends on the slab depth, width, length and load, so the more complete the plans, the more exact the quote.
Start from the design load your structural engineer gives you and the length you need. The slab tool and load table above show which slabs carry that load at that length. We also carry out the load calculations for your project.
It depends on the slab and the load. At 6 kPa, HCS 400 reaches 15.7 m and HCS 200 reaches 9.1 m. The load table above gives every combination.
Yes. Slabs can be cut lengthwise to the exact width your plan needs. Loads for narrowed slabs are recalculated.
Yes. Openings for services, shafts and stairs are formed while the slab is cast. Openings are made only in full 1200 mm wide slabs.
All our standard hollow-core slabs are rated REI 60: they keep their load-bearing capacity, integrity and insulation for at least 60 minutes.
Yes. Our slabs meet building standard requirements and are certified to EU requirements.
Yes. Hollow-core slabs provide heat and sound insulation, and deeper slabs insulate against noise better.
Production takes one month from order confirmation.
With our own transport, up to 24 t per load. Delivery to Sweden takes 2 to 3 days, and unloading on site is arranged by agreement.